Like all of Onduline's roofing sheets, ONDULINE EASYLINE® is made from a flexible and easy to handle material, ensuring an easy and longlasting solution for your roof.

The Onduline material does not contain any asbestos, or harmful chemicals, and is free from metal so it will never rust!

ONDULINE EASYLINE is a compact roofing sheet suitable for DIY roofing projects, such as garden sheds, animal shelters, like chicken coops and dog kennels, as well as wood storage and bike shelters. A great waterproofing solution for all garden outbuildings with a 10 year guarantee. 

EASYLINE Installation Conditions

  • Minimum pitch: 9 degrees
  • Installation is possible on full deck or battens.
  • Pitches of > 5° - 10° : Full deck is required
  • Pitches > 10° : Can be installed on battens with a maximum spacing of 43 cm 

Installation Steps: ONDULINE EASYLINE

Onduline Easyline installation step 1

Step 1: Lay the sheets

Laying in staggered rows avoids the superposition of 4 sheet thicknesses at overlap points.

Always start your first row at the gutter, leaving a maximum 7 cm overhang.
Begin the second row with half an ONDULINE EASYLINE® sheet (cut lengthwise) and carry on with complete sheets.

Onduline Easyline installation step 2

Step 2: Nail or Screw the sheets

Sheets must be fixed onto each of their supporting battens. Every corrugation should be nailed at eaves, overlaps and ridges.

Every second corrugation has to be fixed at the intermediate purlins. The fixing at the intermediate purlins has to be staggered.

Onduline Easyline installation step 3

Step 3: Secure the ridge

Use a ridge batten to support the Onduline ridge piece as shown. The ridge element has to overlap the ONDULINE® sheet min. 12 cm.

Onduline Easyline installation step 4

Step 4: Roof structure

Installation is possible on full deck or battens.
For battens, the roof pitch and occasional load (especially wind and snow) determine the distance between the
battens. The maximum distance is in any case 43 cm for ONDULINE EASYLINE. 

For guidance on how to measure your roof pitch, click here

Onduline Easyline installation step 5

Step 5: End Overlap

Ensure the correct end overlap is secured depending on the pitch and structure of your roof.

The lower the pitch the more overlap is required. 

  • Minimum 30 cm overlap for roof pitches below 10°
  • Minimum 15 cm overlap for roof pitches above 10
Onduline Easyline installation step 6

Step 6: Side overlap

Ensure the correct side overlap is secured depending on the pitch and structure of your roof.

The lower the pitch the more overlap is required. 

  • Minimum 2 corrugations overlap for roof pitches below 10°
  • Minimum 1 corrugattion overlap for roof pitches above 10

Download the full installation steps below or watch the video

EASYLINE Installation Conditions

  • Minimum pitch: 10 degrees
  • Installation is possible on full deck or battens.
  • Pitches of > 5° - 10° : Full deck is required
  • Pitches > 10° : Can be installed on battens with a maximum spacing of 43 cm 

Watch the ONDULINE EASYLINE installation video